What does 13 mean?
High limit switch has opened due to overtemperature condition in heat exchanger.
Common causes
- Restricted airflow - dirty filter
- Failed blower motor
- Blocked supply or return vents
- Heat exchanger crack
- Low refrigerant in heat pump mode
Diagnostic & testing steps
- 1. Check and replace air filter if dirty
- 2. Verify all supply and return vents are open and unobstructed
- 3. Check blower motor operation - should spin freely
- 4. Test blower motor capacitor: expected value on label ±6%
- 5. Measure temperature rise across heat exchanger: should be 35-70°F
- 6. Inspect heat exchanger for cracks (CO risk)
Tools required
- Multimeter
- Capacitor tester
- Thermometer
- Manometer
OEM parts & part numbers
Blower Motor, Blower Capacitor, Air Filter, Limit Switch
Part numbers: EL680-200, HC33GE234
Safety warning
⚠️ CARBON MONOXIDE RISK: Never bypass limit switch. Cracked heat exchanger is a life-threatening hazard.
Try DiagBuddy AI free — instant 30-second diagnostics for technicians.