Carrier heat_pump Error Code 14

Ignition Failure / No Flame

What does 14 mean?

Gas furnace failed to ignite after multiple attempts.

Common causes

Diagnostic & testing steps

  1. 1. Check gas supply valve is open
  2. 2. Inspect hot surface igniter for cracks - resistance should be 40-200 ohms
  3. 3. Clean flame sensor rod with fine steel wool
  4. 4. Test flame sensor: should read 2-6 microamps during flame
  5. 5. Verify gas pressure at manifold: 3.5 in WC for natural gas

Tools required

OEM parts & part numbers

Hot Surface Igniter, Flame Sensor, Gas Valve

Part numbers: LH33ZS004, LH680013, EF32CW054

Safety warning

⚠️ GAS HAZARD: Do not bypass ignition safety controls. Ensure adequate ventilation when checking for gas leaks.