Carrier heat_pump Error Code 41

Pressure Switch Stuck Open

What does 41 mean?

Inducer motor running but pressure switch did not close. Possible blockage in vent or switch failure.

Common causes

Diagnostic & testing steps

  1. 1. Check and clear condensate drain line
  2. 2. Remove pressure switch hose and verify no blockage
  3. 3. Test pressure switch: apply suction - should click closed
  4. 4. Check inducer motor wheel for debris buildup
  5. 5. Verify vent pipe has no blockages

Tools required

OEM parts & part numbers

Pressure Switch, Condensate Drain Assembly, Inducer Motor

Part numbers: HK06WC069, CHPF4860D6, HC21ZE118

Safety warning

⚠️ Never short out the pressure switch — it is a safety device protecting against combustion gases.