Goodman gas_furnace Error Code 2 flashes

Pressure Switch Stuck Open

What does 2 flashes mean?

Inducer is running but pressure switch did not close. Blocked condensate or faulty switch.

Common causes

Diagnostic & testing steps

  1. 1. Disconnect and blow clear the pressure switch hose
  2. 2. Clear condensate drain trap and line
  3. 3. Test pressure switch with manometer - verify closes at rated inches WC
  4. 4. Test inducer motor amp draw
  5. 5. Check for proper flue vent installation

Tools required

OEM parts & part numbers

Pressure Switch, Condensate Drain, Inducer Motor Assembly

Part numbers: B1370163, 0130M00000, B1340018

Safety warning

⚠️ Never bypass the pressure switch. It is a combustion safety device.