Trane heat_pump Error Code 3

High Pressure Fault

What does 3 mean?

Discharge pressure exceeded 590 PSI (R-410A) protection threshold.

Common causes

Diagnostic & testing steps

  1. 1. Measure discharge pressure with manifold gauges
  2. 2. Clean condenser coil - flush with coil cleaner from inside out
  3. 3. Verify condenser fan spins correct direction (top discharge)
  4. 4. Test condenser fan capacitor
  5. 5. Check subcooling: overcharge if >20°F subcooling

Tools required

OEM parts & part numbers

Condenser Fan Motor, Fan Capacitor, Condenser Coil

Part numbers: MOT09025, CPT00449, BAYEV1A24

Safety warning

⚠️ System under extreme pressure when faulted. Do not open refrigerant circuit without proper training.