What does E11 mean?
Heating element circuit open or not heating.
Common causes
- Open heating element coil
- Tripped thermal fuse
- Tripped high-limit thermostat
- Failed heating relay on control
Diagnostic & testing steps
- 1. Test heating element (~10-20 ohms)
- 2. Test thermal fuse for continuity (must be closed)
- 3. Test high-limit thermostat (closed at room temp)
- 4. Replace failed component(s)
Tools required
- Multimeter
- 1/4 inch nut driver
OEM parts & part numbers
Heating Element, Thermal Fuse, High-Limit Thermostat
Part numbers: WE11X29265, WE4M137
Safety warning
⚠️ Element runs at 240VAC. Disconnect power at breaker before testing.