What does F7 E1 mean?
Heating element not heating in expected time.
Common causes
- Open heating element
- Failed thermistor
- Failed control relay
Diagnostic & testing steps
- 1. Test heating element (~15-30 ohms)
- 2. Verify line voltage at element during heat cycle
- 3. Test thermistor
- 4. Replace element if open
OEM parts & part numbers
Heating Element, Thermistor
Part numbers: W10518394
Safety warning
⚠️ Disconnect power before testing.