What does CE mean?
Motor is drawing abnormally high current.
Common causes
- Motor overload
- Items caught in drum
- Stator/rotor issue
- Control board problem
Diagnostic & testing steps
- 1. Reduce load size
- 2. Check for items between inner and outer tub
- 3. Verify drum spins freely
- 4. Test motor current draw with amp clamp
- 5. Check stator/rotor assembly
OEM parts & part numbers
Stator Assembly, Motor Control Board
Part numbers: 4417EA1002Y
Safety warning