What does F19 mean?
Door lock motor cannot lock or unlock during self-clean.
Common causes
- Failed lock motor
- Failed lock switch
- Wiring fault
Diagnostic & testing steps
- 1. Test door lock motor
- 2. Test lock position switch
- 3. Replace door lock assembly
Tools required
- Multimeter
- Phillips screwdriver
OEM parts & part numbers
Door Lock Assembly
Part numbers: AGM73911201