What does nE mean?
Diverter motor (Vario / spray arm distributor) failed to position correctly.
Common causes
- Failed diverter motor
- Stuck diverter valve
- Wiring issue
- Control board fault
Diagnostic & testing steps
- 1. Run diagnostic cycle and listen for diverter motor
- 2. Inspect diverter motor harness
- 3. Test motor — apply 12VDC, should rotate
- 4. Replace diverter assembly if motor is stuck
OEM parts & part numbers
Diverter Motor
Part numbers: EAU61383518
Try DiagBuddy AI free — instant 30-second diagnostics for technicians.