What does F5 E2 mean?
Door lock mechanism has failed to engage properly.
Common causes
- Faulty door lock assembly
- Broken door strike
- Wiring damage
- Control board issue
Diagnostic & testing steps
- 1. Inspect door strike for damage
- 2. Check door lock connector
- 3. Test door lock: 80-120 ohms
- 4. Test for 120VAC at lock connector during cycle
Tools required
- Multimeter
- T20 Torx screwdriver
OEM parts & part numbers
Door Lock Assembly, Door Strike
Part numbers: W10838613, W11188266