What does F7 E1 mean?
Motor not reaching target speed.
Common causes
- Failed motor
- MCU failure
- Overloaded tub
- Loose motor connector
Diagnostic & testing steps
- 1. Check for overloaded tub
- 2. Check motor connector
- 3. Test motor windings
- 4. Check MCU
- 5. Replace motor if failed
OEM parts & part numbers
Drive Motor, Motor Control Unit
Part numbers: W10677715, W10756692