What does F35 mean?
Door lock mechanism failed to engage or release.
Common causes
- Faulty door lock actuator
- Broken door hook
- Wiring issue to lock assembly
- Control board relay failure
Diagnostic & testing steps
- 1. Check door hook alignment and condition
- 2. Test door lock assembly resistance: ~500-1500 ohms
- 3. Verify 230VAC at lock connector during cycle start
- 4. Inspect wiring harness for damage
- 5. Replace door lock assembly if failed
Tools required
- Multimeter
- Torx screwdriver
OEM parts & part numbers
Door Lock Assembly
Part numbers: 6687897, 4842085
Safety warning
⚠️ Unplug before testing door lock mechanism