What does 4C mean?
No water supply detected or water is not filling the tub.
Common causes
- Water supply off
- Kinked hoses
- Clogged screens
- Failed inlet valve
Diagnostic & testing steps
- 1. Check water supply valves are open
- 2. Inspect fill hoses
- 3. Clean inlet screens
- 4. Test inlet valve
- 5. Check water pressure
OEM parts & part numbers
Water Inlet Valve
Part numbers: DC62-00142G, DC62-00233B
Safety warning
⚠️ Turn off water before servicing
Try DiagBuddy AI free — instant 30-second diagnostics for technicians.