What does 8E mean?
Motor is drawing excessive current.
Common causes
- Motor overload
- Stator/rotor issue
- Items caught in drum
- Motor control board failure
Diagnostic & testing steps
- 1. Remove some items from tub
- 2. Check for items between drums
- 3. Test motor current draw
- 4. Check stator assembly
- 5. Test motor control board
OEM parts & part numbers
Stator Assembly, Motor Control Board
Part numbers: DC93-00309A
Safety warning
⚠️ Disconnect power before testing