Sub-Zero refrigerator Error Code EC 60

Compressor Circuit Fault

What does EC 60 mean?

Compressor not starting or running intermittently.

Common causes

Diagnostic & testing steps

  1. 1. Listen for compressor clicking (start relay issue)
  2. 2. Test start relay with multimeter
  3. 3. Test overload protector for continuity
  4. 4. Measure compressor winding resistance: Start 5-15 ohms, Run 2-8 ohms
  5. 5. Check control board output at compressor connector
  6. 6. If windings test OK but still no start, suspect low charge

Tools required

OEM parts & part numbers

Compressor Start Relay, Overload Protector, Start Capacitor

Part numbers: 4201460, 4201470, 4201480

Safety warning

⚠️ Sealed system repairs require EPA 608 certification. Disconnect power before testing compressor.