Viking refrigerator Error Code dF

Defrost Failure

What does dF mean?

Defrost cycle did not complete successfully. Evaporator coil may be iced over.

Common causes

Diagnostic & testing steps

  1. 1. Check for heavy frost on evaporator coil
  2. 2. Test defrost heater for continuity: 20-40 ohms
  3. 3. Test defrost thermostat - should be closed below 40°F
  4. 4. Check defrost control board or timer for proper cycling
  5. 5. Manually initiate defrost cycle from diagnostics mode

Tools required

OEM parts & part numbers

Defrost Heater, Defrost Thermostat, Defrost Control Board

Part numbers: PB070249, PB070250, 002619-000

Safety warning

⚠️ Do not use sharp objects to remove ice from evaporator - risk of refrigerant leak