Viking range Error Code F05

Control Board Relay Failure

What does F05 mean?

Bake or broil relay on control board has failed, causing continuous heating or no heat.

Common causes

Diagnostic & testing steps

  1. 1. If oven is overheating, turn off breaker immediately
  2. 2. Test bake element: 20-50 ohms expected
  3. 3. Test broil element: 15-40 ohms expected
  4. 4. Check for relay clicking when oven is turned on/off
  5. 5. Replace electronic oven control board if relay is stuck

Tools required

OEM parts & part numbers

Electronic Oven Control Board

Part numbers: PB070129, 013142-000

Safety warning

⚠️ If oven is overheating, turn off breaker immediately. Fire risk with stuck relay.