What does F05 mean?
Bake or broil relay on control board has failed, causing continuous heating or no heat.
Common causes
- Welded (stuck closed) relay on control board
- Shorted heating element
- Power surge damage to board
- Component failure on board
Diagnostic & testing steps
- 1. If oven is overheating, turn off breaker immediately
- 2. Test bake element: 20-50 ohms expected
- 3. Test broil element: 15-40 ohms expected
- 4. Check for relay clicking when oven is turned on/off
- 5. Replace electronic oven control board if relay is stuck
Tools required
- Multimeter
- Phillips screwdriver
OEM parts & part numbers
Electronic Oven Control Board
Part numbers: PB070129, 013142-000
Safety warning
⚠️ If oven is overheating, turn off breaker immediately. Fire risk with stuck relay.