What does F29 mean?
Gas valve solenoid circuit has failed (gas dryers only).
Common causes
- Failed gas valve coils
- Wiring issue to gas valve
- Control board relay failure
- Igniter failure causing safety shutoff
Diagnostic & testing steps
- 1. Check igniter - should glow orange when energized
- 2. Test gas valve coils with multimeter - each should read ~300-1000 ohms
- 3. Check wiring to gas valve assembly
- 4. Monitor igniter/flame sequence during operation
- 5. Replace gas valve coils if readings are out of range
Tools required
- Multimeter
- Phillips screwdriver
OEM parts & part numbers
Gas Valve Coil Kit, Igniter
Part numbers: 279834, 279311
Safety warning
⚠️ Turn off gas supply before servicing. Check for gas leaks after repair with soapy water.