What does F8 E4 mean?
Diverter motor is unable to reach the correct position.
Common causes
- Failed diverter motor
- Worn diverter disk
- Debris in sump
- Wiring fault
Diagnostic & testing steps
- 1. Access sump assembly
- 2. Inspect diverter disk for wear or damage
- 3. Test diverter motor with 12VDC
- 4. Replace diverter motor / disk kit
OEM parts & part numbers
Diverter Motor, Diverter Disk Kit
Part numbers: W10538166