What does F9 E2 mean?
Drain system detected issue - possible suds lock or restricted drain.
Common causes
- Excessive suds
- Using wrong detergent type
- Clogged drain system
- Kinked drain hose
Diagnostic & testing steps
- 1. Run rinse/spin cycle to clear suds
- 2. Verify HE detergent is being used
- 3. Reduce detergent amount
- 4. Check drain hose is not kinked
- 5. Clean drain pump filter
OEM parts & part numbers
Drain Pump, Drain Hose
Part numbers: W10536347